Air Shower Testing Standards with HICLOVER Automatic Roll Air Filter Integration
In modern cleanroom facilities, air showers are critical checkpoints for controlling contamination before personnel or materials enter classified areas. To ensure safe and compliant operation, every air shower unit must undergo rigorous testing after installation or commissioning. Increasingly, many manufacturers are coupling air shower systems with HICLOVER Automatic Roll Air Filters, which act as automated prefilters, enhancing airflow stability and extending HEPA life.
Key Testing Standards for Air Showers
-
HEPA Filter Leak Test
After installation, high-efficiency filters must be checked using cleanroom construction and acceptance standards to ensure no leakage. -
Airflow Velocity Uniformity
According to GB 8070 methods, air shower nozzle velocity should be measured at multiple outlets and averaged to confirm uniform coverage. -
Noise Test
Measurements are taken 1,000 mm outside the door and 1,500 mm above the floor; noise levels must comply with applicable occupational standards. -
Illumination
Light levels are measured at 800 mm above the floor, with measurement points every 500 mm. Average illumination must meet prescribed thresholds. -
Pressure Differential
Using a manometer, pressure difference is measured between the inside and outside of the chamber 15 seconds after fan start-up. Testing is repeated three times to ensure accuracy. -
Leakage Current
Electrical safety standards require measurement of leakage current; values must not exceed regulations. -
Grounding Resistance
Grounding resistance between metal parts and the grounding terminal must be within limits, measured with specialized instruments. -
Dielectric Strength
The system must withstand 1-minute application of a 50 Hz sinusoidal AC voltage between power input and metal casing, without breakdown. -
Insulation Resistance
Measured after applying 500 V DC for 1 minute between live parts and the casing; results must comply with safety norms. -
Electronic Interlock Test
-
When the air shower is idle, opening one door must prevent the opposite door from opening.
-
When in operation, both doors must remain locked.
-
In power failure or lock malfunction, both doors should allow manual opening.
Added Value of Automatic Roll Filters
Integrating HICLOVER Automatic Roll Air Filters as a prefiltration stage in air showers provides significant benefits:
-
Stable airflow during velocity tests by preventing filter clogging.
-
Reduced maintenance with automated media replacement, lowering human error in GMP-sensitive industries.
-
Extended HEPA filter lifespan, minimizing downtime in pharmaceutical and semiconductor facilities.
-
Adaptability for global markets, including electronics plants in Vietnam, biotech labs in Europe, and mining support labs in Australia.
Résumé en Français (SEO)
Les cabines de douche à air avec filtre à air en rouleau automatique HICLOVER sont testées pour les fuites HEPA, la vitesse de soufflage, le bruit, la luminosité et la sécurité électrique. Cette solution améliore la stabilité du flux d’air et réduit la maintenance dans l’industrie pharmaceutique et électronique.
Краткое описание по-русски (SEO)
Воздушные душевые с автоматическим рулонным фильтром HICLOVER проходят проверку на утечки HEPA, равномерность воздушного потока, уровень шума и электрическую безопасность. Интеграция фильтра снижает затраты на обслуживание и продлевает срок службы HEPA.
Resumen en Español (SEO)
Las duchas de aire con filtro automático HICLOVER requieren pruebas de fugas HEPA, velocidad de flujo, ruido, iluminación y seguridad eléctrica. La integración con filtros de rollo automático mejora la eficiencia y reduce costos en salas limpias farmacéuticas y electrónicas.
Resumen en Mexicano (LatAm SEO)
Las cabinas de aire con filtro de rollo automático HICLOVER deben cumplir con pruebas de flujo y seguridad. Este sistema ayuda a prolongar la vida de filtros HEPA y mantener condiciones ISO en industrias de México y Latinoamérica.
한국어 요약 (SEO)
HICLOVER 자동 롤 에어 필터가 적용된 에어 샤워는 HEPA 누설, 풍속 균일성, 소음, 조도, 절연 시험을 통과해야 합니다. 이 시스템은 제약, 반도체 산업에서 유지비 절감과 안정적인 공기질을 보장합니다.
在现代洁净室工程中,风淋室是人员与物料进入洁净区前的重要屏障。为确保设备运行安全可靠,风淋室在生产或安装完成后必须进行严格检测。当前,许多厂家将**HICLOVER自动卷绕式空气过滤器**作为预过滤单元配置到风淋室系统中,以保证风量稳定并延长HEPA寿命。
风淋室检测的主要标准
-
高效过滤器检漏:安装完成后应按标准进行检漏,确保无泄漏。
-
喷口风速均匀性:依照GB 8070方法测试,保证风速分布均匀。
-
噪声:在门前1米、离地1.5米处测量,噪声值应符合规范。
-
照度:在距地0.8米位置测定各点照度,取平均值。
-
压差:风机启动15秒后测量室内外压差,重复三次确认。
-
泄漏电流:检测电流值,符合电气安全要求。
-
接地电阻:测量金属部件与接地端之间的电阻,应在规定范围。
-
耐电压:设备应能承受50Hz交流电压1分钟,不得击穿。
-
绝缘电阻:施加500V直流电压1分钟后测量,数值应符合标准。
-
电子联锁:测试两侧门在吹淋与非吹淋状态下的互锁功能,并确认断电时可手动开启。
自动卷绕式过滤器的作用
配置HICLOVER卷绕式过滤器的风淋室能在检测过程中展现更稳定的性能:
-
维持风速测试的稳定性,防止因滤料堵塞导致波动。
-
自动更换滤料,减少人工干预和失误。
-
延长HEPA使用寿命,降低运行维护成本。
-
适用于制药厂、电子厂和矿业实验室等全球市场需求。